Product data sheet
Product characteristics
| Number of inputs and outputs | Number of analog outputs: 2 | ||
|---|---|---|---|
| Measuring range |
| ||
| Process connection | threaded connection G 3/4 DN20 |
Application
| System | gold-plated contacts | |
|---|---|---|
| Application | for industrial applications | |
| Media | water; glycol solutions; Coolants | |
| Medium temperature [°C] | -10...90 | |
| Pressure rating [bar] | 12 | |
| Pressure rating [MPa] | 1.2 | |
| Note on pressure rating |
| |
| MAWP (for applications according to CRN) [bar] | 4.3 |
Electrical data
| Operating voltage [V] | 18...30 DC |
|---|---|
| Current consumption [mA] | < 30 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
Inputs / outputs
| Number of inputs and outputs | Number of analog outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | analog signal |
| Number of analog outputs | 2 |
| Analog current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
| ||
|---|---|---|---|
| Display range |
| ||
| Resolution |
| ||
| Analog start point ASP |
| ||
| Analog end point AEP |
| ||
| In steps of |
| ||
| Measuring dynamics | 1:20 |
Temperature monitoring
| Measuring range [°C] | -10...90 |
|---|---|
| Display range [°C] | -30...110 |
| Resolution [°C] | 0.5 |
| Analog start point [°C] | -10...70 |
| Analog end point [°C] | 10...90 |
| In steps of [°C] | 0.5 |
Accuracy / deviations
Flow monitoring
| Accuracy (in the measuring range) | ± 2 % MEW; (water) |
|---|---|
| Repeatability | ± 0,5 % MEW |
Temperature monitoring
| Accuracy [K] | ± 1 |
|---|
Reaction times
Flow monitoring
| Response time [s] | 1; (dAP = 0) |
|---|---|
| Damping process value dAP [s] | 0...5 |
Temperature monitoring
| Dynamic response T05 / T09 [s] | T09 = 6 |
|---|
Software / programming
| Parameter setting options | Damping for the analog output dAA; Display unit |
|---|
Operating conditions
| Ambient temperature [°C] | 0...60 | ||
|---|---|---|---|
| Note on ambient temperature |
| ||
| Storage temperature [°C] | -20...80 | ||
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC |
| ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CPA approval |
| ||||||||||||
| Shock resistance |
| ||||||||||||
| Vibration resistance |
| ||||||||||||
| MTTF [years] | 342 | ||||||||||||
| UL approval |
| ||||||||||||
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 483.5 |
|---|---|
| Material | stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM |
| Tightening torque [Nm] | 30 |
| Process connection | threaded connection G 3/4 DN20 |
Remarks
| Remarks |
| ||
|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection