Product characteristics
| Output function | normally open |
|---|
| Sensing range [mm] | 15 |
|---|
| Housing | Threaded type |
|---|
| Dimensions [mm] | M30 x 1.5 / L = 81 |
|---|
Electrical data
| Operating voltage [V] | 20...250 AC/DC |
|---|
| Protection class | II |
|---|
| Reverse polarity protection | no |
|---|
Outputs
| Output function | normally open |
|---|
| Max. voltage drop switching output DC [V] | 6 |
|---|
| Max. voltage drop switching output AC [V] | 6.5 |
|---|
| Minimum load current [mA] | 5 |
|---|
| Max. leakage current [mA] | 2.5 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) |
|---|
| Permanent current rating of switching output AC [mA] | 250; (350 (...50 °C)) |
|---|
| Permanent current rating of switching output DC [mA] | 100 |
|---|
| Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
|---|
| Switching frequency AC [Hz] | 25 |
|---|
| Switching frequency DC [Hz] | 50 |
|---|
| Short-circuit proof | no |
|---|
| Overload protection | no |
|---|
Monitoring range
| Sensing range [mm] | 15 |
|---|
| Real sensing range Sr [mm] | 15 ± 10 % |
|---|
| Operating distance [mm] | 0...12.1 |
|---|
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.3 / copper: 0.2 |
|---|
| Hysteresis [% of Sr] | 1...15 |
|---|
| Switch-point drift [% of Sr] | -10...10 |
|---|
Operating conditions
| Ambient temperature [°C] | -25...80 |
|---|
| Protection | IP 67 |
|---|
Tests / approvals
| EMC | | EN 60947-5-2 | | | EN 55011 | class B |
|
|---|
| MTTF [years] | 607 |
|---|
Mechanical data
| Weight [g] | 180 |
|---|
| Housing | Threaded type |
|---|
| Mounting | non-flush mountable |
|---|
| Dimensions [mm] | M30 x 1.5 / L = 81 |
|---|
| Thread designation | M30 x 1.5 |
|---|
| Material | PBT |
|---|
Displays / operating elements
| Display | | Switching status | 1 x LED, yellow |
|
|---|
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
|---|
Remarks
| Remarks | | Recommendation: check the unit for reliable function after a short circuit. |
|
|---|
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connection | Cable: 2 m, PVC; 2 x 0.5 mm² |
|---|