Product characteristics
| Electrical design | PNP |
|---|
| Output function | complementary |
|---|
| Sensing range [mm] | 15 |
|---|
| Housing | Threaded type |
|---|
| Dimensions [mm] | M30 x 1.5 / L = 125 |
|---|
Electrical data
| Operating voltage [V] | 10...30 DC |
|---|
| Current consumption [mA] | < 20 |
|---|
| Protection class | III |
|---|
| Reverse polarity protection | yes |
|---|
| Measuring principle | capacitive |
|---|
Outputs
| Electrical design | PNP |
|---|
| Output function | complementary |
|---|
| Max. voltage drop switching output DC [V] | 2.5 |
|---|
| Max. leakage current [mA] | 0.1 |
|---|
| Permanent current rating of switching output DC [mA] | 200 |
|---|
| Switching frequency DC [Hz] | 10 |
|---|
| Short-circuit proof | yes |
|---|
| Overload protection | yes |
|---|
Monitoring range
| Sensing range [mm] | 15 |
|---|
| Sensing range adjustable | yes |
|---|
| Factory setting sensing range [mm] | 15 |
|---|
| Real sensing range Sr [mm] | 15 ± 10 % |
|---|
Accuracy / deviations
| Hysteresis [% of Sr] | 1...15 |
|---|
| Switch-point drift [% of Sr] | -20...20 |
|---|
Operating conditions
| Ambient temperature [°C] | -20...60 |
|---|
| Protection | IP 65; IP 67 |
|---|
Tests / approvals
| ATEX marking | II 3D Ex tc IIIC T90°C Dc X |
|---|
| EMC | | EN 61000-4-2 ESD | kV / 8 kV AD | | EN 61000-4-3 HF radiated | 3 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-6 HF conducted | 3 V | | EN 55011 | class B | | IEC 60255-5 | 1 kV line to line, Ri: 500 Ohm |
|
|---|
| MTTF [years] | 463 |
|---|
Mechanical data
| Weight [g] | 155 |
|---|
| Housing | Threaded type |
|---|
| Mounting | non-flush mountable |
|---|
| Dimensions [mm] | M30 x 1.5 / L = 125 |
|---|
| Thread designation | M30 x 1.5 |
|---|
| Material | PBT; PA |
|---|
Displays / operating elements
| Display | | Switching status | 1 x LED, yellow |
|
|---|
Electrical connection
| Connection | terminals: 0.34...1.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5 |
|---|