Product data sheet
| Model number | S-120 series |
| AC input voltage range | 85-132VAC/176-264VAC, selected by switch, 47-63Hz; 248-370VDC |
| Input current | 0.8A/115V, 0.45A/230V |
| AC inrush current | Cold-start current: 30A/115V, 60A/230V |
| Leakage current | 1mA/240VAC max |
| Overload proctection | 105%-150% Type:Foldback current limiting Rest:auto-recovery |
| Temperature coefficient | ±0.03%/℃ (0-50℃) |
| Setup rise hold up time | 1s, 15ms, 30ms |
| Vibration | 10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes |
| Dielectric strength | 1.5KVac, 50/60 Hz for 1 min between input and output 1.5KVac, 50/60 Hz for 1 min between input and enclosure 0.5KVac, 50/60 Hz for 1 min between output and enclosure |
| Isolation resistance | 100MΩ min. at 500 VDC |
| Working temperature humidity | -10℃-60℃ (Refer to output characteristic figure), 20%-90%RH |
| Store temperature humidity | -20℃-85℃, 10%-95%RH |
| External dimension | 199x98x38 mm |
| Weight | 0.65kg |
| Safety standards | UL1012 (not apply to mark) |
| EMC standards | FCC part 15J condition level B |
Tags:
Zorx-byj20240709